Login| Register|
Currency:
| Contact Us Cart

New OSN 3500 Does Not show All Its Boards Coz It Has An MSTP

Mar. 01, 2019

 A Brand New Huawei OSN3500 equipment Only created, generated Following the upload Performance That the NE error: Invalid parameters error Signal: 38722; along with a Few boards did Not Seem or turned Gray.

The troubleshooting developed was:

1. Run in Navigator the commands

2. 2. Try to create the NE with only one SCC board.

3. Downgrade the NE to a pure SDH version.

There was two troubles, first the NE had two SCC boards that didn’t synchronize because each one had a different ID, and the second issue was a mistake made by the person that upgrade the element on site; he put on the equipment the version V2R11C00SPH303 which is a version for Huawei MSTP equipments, and the customer network only managed SDH elements.

If you want to know the Huawei OSN3500 SDH Price, please call us now.